Working conditions
Clean cold or hot fluid, fluid with non-solid particles and non-fiber, inflammable and explosive one are not allowed.Â
Fluid temperature: -15 centi degree~+120 centi degree
Working temperature: ≤ +40 centi degree
The minimum pressure from inlet: Npshr+0.5mh2o
Application scope
Municipal water supply and pressurization
Industrial cycle system and processing system
Boiler water feed and cooling fluid system
Home water supply
Environmental water treatment, osmosis system
Agriculture irrigation and deprivation
Various cleaning, such as factory building cleaning
Other special applications
Technical data
CDL8/CDL(F)8Â Performance Parameters
 Type
Motor power  (kw)Â
QÂ Â Â Â Â m3/h
5
6
7
8
9
10
11
12
Â
CDL(F)8-20
0.75
   H       (m)
21
20
19
18
17
16
14
13
Â
CDL(F)8-30
1.1
31
30
28
27
25
24
21
19
Â
CDL(F)8-40
1.5
41
40
37
36
34
32
29
26
Â
CDL(F)8-50
2.2
51
49
47
45
42
0
36
33
Â
CDL(F)8-60
2.2
61
59
56
54
51
48
43
39
Â
CDL(F)8-70
3
71
69
65
63
59
56
51
46
Â
CDL(F)8-80
3
81
78
75
72
68
6
58
52
Â
CDL(F)8-90
4
91
88
84
81
76
72
65
59
Â
CDL(F)8-100
4
101
98
93
90
85
80
73
65
Â
CDL(F)8-110
4
111
107
103
99
93
88
80
72
Â
CDL(F)8-120
4
121
117
112
108
102
96
87
78
Â
CDL(F)8-130
5.5
131
127
121
117
110
10
95
85
Â
CDL(F)8-140
5.5
141
136
131
126
119
112
102
91
Â
CDL(F)8-150
5.5
151
146
140
135
127
120
109
98
Â
CDL(F)8-160
5.5
161
156
149
144
136
128
117
104
Â
CDL(F)8-170
7.5
171
165
159
153
144
136
124
111
Â
CDL(F)8-180
7.5
181
175
168
162
153
144
131
117
Â
CDL(F)8-190
7.5
191
185
177
171
161
152
139
124
Â
CDL(F)8-200
7.5
201
195
187
180
170
160
146
130
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
More model technical data, please contact with us !
Contact Us
Â
Working conditions
Clean cold or hot fluid, fluid with non-solid particles and non-fiber, inflammable and explosive one are not allowed.Â
Fluid temperature: -15 centi degree~+120 centi degree
Working temperature: ≤ +40 centi degree
The minimum pressure from inlet: Npshr+0.5mh2o
Application scope
Municipal water supply and pressurization
Industrial cycle system and processing system
Boiler water feed and cooling fluid system
Home water supply
Environmental water treatment, osmosis system
Agriculture irrigation and deprivation
Various cleaning, such as factory building cleaning
Other special applications
Technical data
CDL8/CDL(F)8Â Performance Parameters
 Type
Stainless Steel Multistage Vertical Centrifugal Pump
Model NO.: QDLF
Position of Pump Shaft: Vertical Pump
Pump Casing Combined: Verticaljoint Surface Pump
Mounting Height: Suction Centrifugal
Usage: Pump
Material: Stainless Steel
Pressure: High Pressure
Application: Clean Water/Raw Water
Flow Range: 2-250 M3/H
Head Range: 8-500 M
Voltage: 220V/380V/440V
Speed: 1450-3500rpm
Motor Power: 0.75-110kw
Inlet&Outlet: Dn25-150mm
Standard: Yes
Transport Package: Standard Pacakge
Origin: Wenzhou, China
HS Code: 8413709990
Model NO.: QDLF
Position of Pump Shaft: Vertical Pump
Pump Casing Combined: Verticaljoint Surface Pump
Mounting Height: Suction Centrifugal
Usage: Pump
Material: Stainless Steel
Pressure: High Pressure
Application: Clean Water/Raw Water
Flow Range: 2-250 M3/H
Head Range: 8-500 M
Voltage: 220V/380V/440V
Speed: 1450-3500rpm
Motor Power: 0.75-110kw
Inlet&Outlet: Dn25-150mm
Standard: Yes
Transport Package: Standard Pacakge
Origin: Wenzhou, China
HS Code: 8413709990
Product overview
This is a latest version of pump, having the feature of energy-saving, environmental protection, less space demand easy installation, stable performance and convenient maintenance. The pump is made of 304 materials with excellent quality; Such ideal pump can substitute for old version of pressure compensated pump. Product overview
This is a latest version of pump, having the feature of energy-saving, environmental protection, less space demand easy installation, stable performance and convenient maintenance. The pump is made of 304 materials with excellent quality; Such ideal pump can substitute for old version of pressure compensated pump.Â