Wuxi Changchen Technology Co., Ltd , https://www.wxchangchen.com
The main cable conductor is free of joints (the joints are already manufactured and closed at the branch point at the factory),
The pre-branch cable distribution is similar to the busbar power distribution method, but the cable has good seismic resistance, airtightness, and waterproof performance. It has a small footprint and is easy to install. The disadvantage is that quality faults are difficult to repair in the field. The cable is processed for specific engineering conditions and does not have Interchangeability.
The use of branch cable, branch cable YFD series prefabricated branch cable has the advantages of excellent power supply reliability. Main cable conductor has no joints, good continuity, reducing the failure point;
Branch joints have strict technical standards and inspection requirements, as well as a strict quality assurance system;
·The branch joints are manufactured by the entire process of mechanization in the factory, which greatly reduces the quality of the artifacts caused by human factors;
·Branch joint structure is reasonable and adopts advanced LYZ process to produce, the contact resistance is very small, not affected by thermal expansion and contraction;
• The jacket is completed in a short time, avoiding contact with the steel core exposed to oxidation in the air for a long time, resulting in changes in contact resistance.
Can significantly reduce distribution costs, more varieties and specifications, flexible selection, any combination;
Branch joints can be set arbitrarily according to the floor needs;
· Compared with the busway, the construction cost can be reduced. And the technical and economic indicators are high and the comprehensive economic benefits are significant;
Main cable from 10mm2 to 1200mm2, branch cable from 10mm to 95mm optional combination;
·There are many kinds of cables, such as MY rubber branch cables, VV, ZR-VV, NH-VV, YJV, ZR-YJV, NH-YJV, etc. It is possible to choose low installation environment requirements, convenient construction, and low use environment requirements. Low installation accuracy;
· Because of its small bending radius. Greatly reduce the difficulty of installation and reduce the space size;
Occupies a small area of ​​construction, is conducive to the effective use of the building area, there is no requirement for the size of the civil space;
The installation is simple and convenient, installation technology requirements are not high, the installation of equipment requires only a common roll-field machine, and the installation cycle is short,
Pre-branch cable use
Pre-branched cables are mostly used in high-rise building distribution trunks (trunk-type distribution methods).